MoDOT's workspace works with OpenRoads Designer version 10.12.02.04 or higher. Any previous versions are not compatible with this environment. QuanTab has been included in the consultant workspace. This add-on application gives you the option to create quantities in a certain excel sheet and then imports data into the dgn file while adhering to our MoDOT CADD detailing standards. MoDOT will provide QuanTab as-is without warranty. MoDOT will not provide support for the QuanTab application and will not be liable for what the QuanTab application does or creates. Note: when workspace is on a network location, make sure unblock (right click - properties - general folder) the two quantab files so it will run properly in ORD. You will get the "Unknown keyin or command" in ORD if those files are blocked. MoDOT printing and configuration files has been included in the consultant workspace. MoDOT will provide our printing setup as-is without warranty. MoDOT will not provide support and will not be liable for what the MoDOT printing setup does or creates. ************************************************************************************************************* ***00/00/00 version*** ************************************************************************************************************* Updated "Generic Node - Headwall - XX Vertical Opening" cells to be at the correct elevation or with terrian model (was being placed deeper than the defined elevation or selected terrian model) Updated Generic Node - Headwall - XX Vertical Opening nodes for the "Use Slope of Surface" option to "False" for the default in the Feature Definitions. Updated Mast Arms cells to have correct diameter base (previously was 2.789, now 3' per standard plans) Updated ITL (ASK KEVIN ON CHANGES DONE WITH IT) Remove POP.dgn files that are no longer needed. (CADD_Standards\ORD Standards\Consultant Workspace - 10.12.02.04\MoDOT_ORD_v10.12.02.04\Standards\Seed\Roadway\POP Sign Details) Updated and added more TAs (Typical Applications for Traffic Control) under Standards/Seed/Roadway/TAs ************************************************************************************************************* ***10/01/2024 version*** ************************************************************************************************************* Added USTN Capability variables Added Laminated Neoprene Bearing Pad cell for Bridge (MoDOT CADD Detailing Standards/Bridge/Intermediate Bents) Renamed J1.16 MSE Wall System Data Table to J1.21 MSE Wall System Data Table for Bridge (MoDOT CADD Detailing Standards/Bridge/Detailing Notes) Updated settings to have Time of Concentration display in minutes instead of hours (Drainage.dgnlib) Updated D2BS Sheet Updated MoDOT Superelevation Rules Files.xml file Added AutoTurn-XX and Scratch 6-10 levels Added more TAs (Typical Applications for Traffic Control) under Standards/Seed/Roadway/TAs * TA-0 * TA-01 * TA-03&5 * TA-03&6 * TA-10 * TA-Side_Roads Added _D-Signing.xlsm excel file for the D-29 & D-30 sheets Added Low_Distortion_Projection_Systems.dty file. (This contains the coordinate systems for the I-70 and I-44 corridors and replaces the I-70_Corridor.dty file contained in previous workspace versions) ************************************************************************************************************* ***03/01/2024 version*** ************************************************************************************************************* Updated 3D drainage cells to have ability to connect to center of circular structures instead of inner wall only Added generic nodes (2'-15') in Drainage nodes for doing drainage analysis Removed unused 3D cells for RW labels that were used previously Removed traffic control signs with flags in CADD Detailing Standards (not needed anymore per EPG changes) Minor updates and fixes with feature definitions Updated ITL for how guardrail is placed Added updated county maps (PDF) and broke out folder directory (Current and Obsolete) Added POP_2026.dgn for standard sign details Added curve label for alignments that have spiral-curve-spiral curves. The label placed at the PI of the curve. Added XS annotation group to add utility labels on the drawing models for cross sections. Changed "Use Slope of Surface" option to "False" for headwall feature definitions in the Drainage dgnlib. Added TAs (Typical Applications for Traffic Control) under Standards/Seed/Roadway/TAs Updated EAV Table (End Area Volume) to make it larger to be able to see easier when printed out. Added "Safety Edge" label to be placed on cross sections when needed.